The Rainwater Recycling/ Reclamation Systems accept rainwater and provide a treated water supply for points of use in and around the facility. Rainwater is supplied from the building’s recycled water collection network and routed to the interior Rainwater Collection tank.

Technical Overview:

System Type

Single pump system

Product Compatibility

M1, M2, M3, M4, MD1, MD3, MC2, MC3

Frame Material

Polyethylene

Mounting Position

Floor or Wall

PSI

150

Bar

10.3

No PDF available.

Product Information

Museum- Cistern Storage Style Rainwater Recycling System

Type: Cistern Storage Style Rainwater Recycling System is located in Washington DC.

Details: The Rainwater Recycling/ Reclamation Systems accept rainwater and provide a treated water supply for points of use in and around the facility. Rainwater is supplied from the building’s recycled water collection network and routed to the interior Rainwater Collection tank. 

The Cistern is 15,000 gal. concert vault. Burt Process Equipment supplied pumps in the cistern pressurize the water through the treatment system to a clean water tank. The clean water tank is recirculated to maintain purity. A separate booster pump distributes the water to the points of use. 

Pharmaceutical Company Cistern Storage Style Rainwater Purification System

Type: Cistern Storage Style Rainwater Purification System is located in Cambridge Massachusetts.

Details: The Rainwater Reclamation System accepts rainwater and reject process water and provides treated water supply for points of use in and around the facility. 

Rainwater is supplied from the building’s recycled water collection network and routed to exterior rainwater collection tanks. Reverse osmosis rejects water is collected in the clean water storage tank. 

Data center reclaim water system

Type: Cistern Storage Style Rainwater/Reclaim Water Purification System is located in Mexico

Details: Multiple Reclaimed Water System for Data Center Cooling Plant Make-Up. These systems are designed to reclaim water from multiple sources to offset the large cooling demand of the data center. These include rainwater, groundwater, and non-potable city water sources. Each system is designed to treat its unique water source. System flow rates range from 50gpm to 300gpm. Water is utilized in the building cooling system.

University Building- Direct Storage Style Rainwater Recycling System

Type: Direct Storage Style Rainwater Recycling System is located in NY.

Details: The Rainwater Reclamation Systems accept rainwater and provide a treated water supply for points of use in and around the facility. Rainwater is supplied from the building’s recycled water collection network and routed to the interior Rainwater Collection tank. The interior rainwater tank has a prefilter to remove heavy sediment from the roof collection system. The water is then pressurized through the treatment system to points of use. The rainwater is used for flushing fixtures.

Beverage Producer – Direct Storage Style Rainwater Reclamation or Harvesting Systems 

Type:  Direct Storage Style Rainwater Reclamation Systems located in Atlanta Georgia.

Details: The Rainwater Harvesting Systems accepts collected rainwater and provides treated water supply for points of use in and around the facility. Rainwater is supplied from the building recycled water collection network and routed to exterior Rainwater Collection tanks. 

Pharmaceutical Cistern Storage Style Rainwater Purification System 

Type: Cistern Storage Style Rainwater Purification System is located in Cambridge Massachusetts.

Details: The Rainwater Purification or Reclamation System accepts rainwater and reject process water and provides treated water supply for points of use in and around the facility.

Rainwater is supplied from the building’s recycled water collection network and routed to exterior rainwater collection tanks. Reverse osmosis rejects water is collected in the clean water storage tank.

Beverage Producer – Direct Storage Style Rainwater Reclamation or Harvesting Systems 

Type: Cistern Storage Rainwater Recovery System is located in Manhattan NYC.

Details: The Rainwater Recovery or Reclamation Systems accept rainwater and provide a treated water supply for points of use in and around the facility. Rainwater is supplied from the building’s recycled water collection network both from the roof as well as from the plaza and routed to underground rainwater collection tanks. The water is filtered and sanitized at 500gpm and the clean water storage tank is recirculated over 2 times an hour per local codes. The system utilizes a full maintenance-free set-up with automatic UV cleaning wipers and complete low-flow backwash filters. The filters back-wash with the only 200gal. to be water conservative. The water is dyed blue per local code. The Rainwater Recovery System is automated and is controlled by a Main PLC Control panel. Skid piping is copper.

University – Direct Storage Style Rainwater Recycling System 

Type: Direct Storage Style Rainwater Recycling System is located in Upstate NY.

Details: The Rainwater Recycling/ Reclamation Systems accept rainwater and provide a treated water supply for points of use in and around the facility.

Rainwater is supplied from the building’s recycled water collection network and routed to the interior Rainwater Collection tank. 

Features

Museum- Cistern Storage Style Rainwater Recycling System
The Unit Features:

  • Water Filtration to 40 micron utilizing reclaim water back-washable filters 
  • Fully redundant reclaim transfer and distribution pumps 
  • PLC controlled for integration and communication to the building BMS
  • 316 SS UV with pneumatically controlled wiper and intensity monitors
  • Clean water tank 
  • Back-up city water supply

Cistern Info: (1) Belowground 15.000 gal. tank
Use: Flushing fixtures and Irrigation

Pharmaceutical Company Cistern Storage Style Rainwater Purification System

The Unit Features:

  • Water Filtration to 50 micron utilizing cartridge filters
  • Fully redundant distribution and transfer pumps 
  • PLC controlled for integration and communication to the building BMS
  • 316 SS UV with pneumatically controlled wiper and intensity monitors
  • Chlorine injection and recirculation system with a built-in recirculation tank
  • Dye injection for reclaim water identification. 

Cistern Info: (2) Above Ground 15,000 gal. thermoplastic tanks
Use: Flushing Fixtures and Cooling tower feed

Data center reclaim water system

The Unit Features:

  • Water Filtration to 40 micron utilizing reclaim water back-washable filters 
  • Fully redundant reclaim transfer and distribution pumps 
  • PLC controlled for integration and communication into the Data Center Control System
  • Secondary design features for potable water make-up by the system as needed 
  • Redundant 316 SS transfer pumps
  • 316 SS UV with pneumatically controlled wiper and intensity monitors
  • Low flow back-washable filters that can stay in operation while backflushing is occurring 

Cistern Info: (2) Above Ground 500,000 gal. tanks

Water Source: Rain Water Runoff from the Roof, groundwater, and non-potable city water

Use: Cooling tower feed

University Building- Direct Storage Style Rainwater Recycling System

Type: Direct Storage Style Rainwater Recycling System is located in NY.

Details: The Rainwater Reclamation Systems accept rainwater and provide a treated water supply for points of use in and around the facility. Rainwater is supplied from the building’s recycled water collection network and routed to the interior Rainwater Collection tank. The interior rainwater tank has a prefilter to remove heavy sediment from the roof collection system. The water is then pressurized through the treatment system to points of use. The rainwater is used for flushing fixtures.

The Unit Features:

  • Water Filtration to 50 micron utilizing cartridge filters
  • Fully redundant distribution pumps 
  • PLC controlled for integration and communication to the building BMS
  • 316 SS UV with pneumatically controlled wiper and intensity monitors
  • Dye injection for reclaim water identification. 

Cistern Info: (1) Above ground 3000 gal. polypropylene tank

Water Source: Rain Water Runoff from the Roof

Use: Flushing Fixtures

Beverage Producer – Direct Storage Style Rainwater Reclamation or Harvesting Systems 

Type:  Direct Storage Style Rainwater Reclamation Systems located in Atlanta Georgia.

Details: The Rainwater Harvesting Systems accepts collected rainwater and provides treated water supply for points of use in and around the facility. Rainwater is supplied from the building recycled water collection network and routed to exterior Rainwater Collection tanks. The system operates in three different modes of 

Service:

  • Rainwater supply to Flushing Fixtures
  • Rainwater supply to Cooling Tower(s)
  • Circulation return to Rainwater Collection tanks

Cistern Info: (2) Above Ground 15,000 gal. thermoplastic tanks

Water Source: Rain Water Runoff from the Roof

Use: Flushing Fixtures and Cooling tower feed

Pharmaceutical Cistern Storage Style Rainwater Purification System 

Type: Cistern Storage Style Rainwater Purification System is located in Cambridge Massachusetts.

Details: The Rainwater Purification or Reclamation System accepts rainwater and reject process water and provides treated water supply for points of use in and around the facility.

Rainwater is supplied from the building’s recycled water collection network and routed to exterior rainwater collection tanks. Reverse osmosis rejects water is collected in the clean water storage tank. The system operates in four different modes of rainwater.

Service:

  • Reclaimed water supply to Flushing Fixtures
  • Reclaimed water supply to Cooling Tower(s)
  • Reclaimed water supply to Flushing fixtures and Cooling Towers
  • Circulation of chlorine blend tank.

Cistern Info: (2) Above Ground 15,000 gal. thermoplastic tanks

Water Source: Rain Water Runoff from the Roof

Use: Flushing Fixtures and Cooling tower feed

Beverage Producer – Direct Storage Style Rainwater Reclamation or Harvesting Systems 

Type: Cistern Storage Rainwater Recovery System is located in Manhattan NYC.

Details: The Rainwater Recovery or Reclamation Systems accept rainwater and provide a treated water supply for points of use in and around the facility. Rainwater is supplied from the building’s recycled water collection network both from the roof as well as from the plaza and routed to underground rainwater collection tanks. The water is filtered and sanitized at 500gpm and the clean water storage tank is recirculated over 2 times an hour per local codes. The system utilizes a full maintenance-free set-up with automatic UV cleaning wipers and complete low-flow backwash filters. The filters back-wash with the only 200gal. to be water conservative. The water is dyed blue per local code. The Rainwater Recovery System is automated and is controlled by a Main PLC Control panel. Skid piping is copper.

Cistern Info: (1) Below Ground 50,000 gal. welded stainless steel tank

Water Source: Rain Water Runoff from the roof and plaza

Use: Flushing Fixtures

University – Direct Storage Style Rainwater Recycling System 

The Unit Features:

  • Water Filtration to 40 micron utilizing reclaim water back-washable filters 
  • Fully redundant reclaim transfer and distribution pumps 
  • PLC controlled for integration and communication into the Data Center Control System
  • Secondary design features for potable water make-up by the system as needed 
  • Redundant 316 SS transfer pumps
  • 316 SS UV with pneumatically controlled wiper and intensity monitors
  • Low flow back-washable filters that can stay in operation while backflushing is occurring 

Cistern Info: (1) Above Ground 3,000 gal. thermoplastic tanks
Water Source: Rain Water Runoff from the Roof
Use: Flushing Fixtures

University Building- Direct Storage Style Rainwater Recycling System

The Unit Features:

  • Water Filtration to 50 micron utilizing cartridge filters
  • Fully redundant distribution pumps 
  • PLC controlled for integration and communication to the building BMS
  • 316 SS UV with pneumatically controlled wiper and intensity monitors
  • Dye injection for reclaim water identification. 

Cistern Info: (1) Above ground 3000 gal. polypropylene tank
Water Source: Rain Water Runoff from the Roof
Use: Flushing Fixtures

Specifications

Service:

  • Rainwater supply to Flushing Fixtures
  • Rainwater supply to Cooling Tower(s)
  • Circulation return to Rainwater Collection tanks
  • Reclaimed water supply to Flushing Fixtures
  • Reclaimed water supply to Cooling Tower(s)
  • Reclaimed water supply to Flushing fixtures and Cooling Towers
  • Circulation of chlorine blend tank.
  • Rainwater supply to Flushing Fixtures
  • Circulation return to Rainwater Collection tanks